Temperature | Name | NO | Kinematic viscosity |
Solidifying point |
Standard |
-30--10 | Refrigerator oil | 11.5-14.5(50ºC) | -40ºC | ZBE34003-86 | |
-10-0ºC | Turbine oil | N22 | 20-23(50ºC) | -10ºC | GB2537-81 |
0-30ºC | Cylider oil (30%) Machine oil (70%) |
HG-24+HJ-50 | 20-28(100ºC) 47-53(50ºC) |
15ºC -10ºC |
GB447-77 GB443-84 |
Malfunction | Cause | Solution |
Difficult to operate |
Low air pressure | If pipeline is over-burden,reduce machine number |
check air pipe dia and valve switch whether too small,if so ,change it. | ||
If air pipe is too long, cut short | ||
Lack of Air-leg thrust | Enlarge angle between air-leg and floor | |
Seal ring abrase,change it | ||
Trigger or change-over valve cann't move .mend it at once | ||
Water intake | Water pressure is higher than air pressure, water flow into cylinder ,damage lubrication. Lower water pressure immediately | |
Water injection system out of work ,water and air run into machine,check it at once | ||
Muffler icing | Thaw out | |
Bad lubricate | No lubricating oil, oil it | |
Block oil hose , clean and blow off dirty | ||
If use wrong lubricating oil ,do use standard oil. | ||
Water flow out from front head.damage normal lubrication | If water tube broken,change it | |
If drill hose is blocked or too small, change it | ||
Water tube dia ≤3mm | ||
Part abrase | If cylinder and piston surface abrase, rubdown it with oilstone | |
If distributing valve abrase,change it | ||
If piston nut rotation sleeve and other parts damage,change it | ||
Dismantle water tube | Assemble it | |
Lubricating too much | Adjust it | |
Water intake | Find out trouble and resolve | |
Water tube broken |
Piston damage or Shank midlevel outlet position is wrong | Change piston or drill |
Clearance is too large between shank and drill sleeve | Hex size abrase over 25mmm,change another one | |
Water tube is too long | Adjust water tube length | |
Shank hose is too low | As draw specification process it | |
Out of use | Water pressure is too high | Lower water pressure (≤0.1Mpa) |
Block hose | Drill through hose | |
Parts rust | Clean and remove rust | |
Srping out of use | Change it | |
Rubber ring damage | Change it | |
Drill broken |
Air pressure is too high | Lower air pressure |
Operate machine immediately | Operate it increasingly | |
Drill is flect | Change it | |
Angle is too small | As draw process shank | |
Heat treating trail | Improve process |
Temperature | Name | NO. | Kinematic viscosity |
Solidifying point |
Standard |
-30--10 | Refrigerator oil | 11.5-14.5(50ºC) | -40ºC | ZBE34003-86 | |
-10-0ºC | Turbine oil | N22 | 20-23(50ºC) | -10ºC | GB2537-81 |
0-30ºC | Cylider oil (30%) Machine oil (70%) |
HG-24+HJ-50 | 20-28(100ºC) 47-53(50ºC) |
15ºC -10ºC |
GB447-77 GB443-84 |
Malfunction | Cause | Solution |
Difficult to operate |
Low air pressure | If pipeline is over-burden,reduce the operating machines and eliminate the leak of the pipe. |
check air pipe dia and valve switch whether too small,if so ,change it. | ||
If air pipe is too long ,cut short it. | ||
lack of Air-leg thrust | Enlarge angle between air-leg and floor. tighten the rack and pipe. Change the broken pressure regulation valve |
|
Seal ring abrase,change it in time | ||
Trigger or change-over valve cann't move .mend it at once | ||
Water intake | Water pressure is higher than air pressure, the water flow into cylinder ,damage the usual lubrication. play down the water pressure immediately. | |
Water injection system out of work ,water and air run into machine,check it at once. Change the break off water needle. Change the small water needle's aperture(bigger than 3mm) |
||
Muffler icing | Thaw out | |
Bad lubricate | Unworking without oil and don't use lubricate grease. | |
Block oil hose , clean and blow off dirty | ||
Use standard oil. | ||
Water flow out from front head.damage normal lubrication | If water tube broken,change it | |
If drill hose is blocked or too small, change it | ||
Water tube dia ≤3mm | ||
Parts abrase | If cylinder and piston surface abrase, rubdown it with oilstone | |
If distributing valve abrase,change it | ||
If piston nut rotation sleeve and other parts damage,change it | ||
Dismantle water tube | Assemble it | |
Lubricating too much | Adjust it | |
Water intake | Find out trouble and resolve | |
Water tube broken |
Piston damage or Shank midlevel outlet position is wrong | Change piston or drill |
Clearance is too large between shank and drill sleeve | Hex size abrase over 25mmm,change another one | |
Water tube is too long | Adjust water tube length | |
Shank hose is too low | As draw specification process it | |
Out of use | Water pressure is too high | Play down the water pressure (≤0.1Mpa) |
Block hose | Drill through hose | |
Parts rust | Clean and remove rust | |
Srping out of use | Change it | |
Rubber ring damage | Change it | |
Drill broken |
Air pressure is too high | Lower air pressure |
Operate machine immediately | Operate it increasingly | |
Drill is flect | Change it | |
Angle is too small | As draw process shank | |
Heat treating trail | Improve process |