Customization: | Available |
---|---|
Application: | Pneumatic Breakers |
Condition: | New |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Temperature | Name | No | Flash point |
Kinematic viscosity |
Solidifying point |
Standard |
10-30ºC | Machine oil | N46 | 180ºC | 41.4-50.6(40ºC) | -10ºC | GB443-84 |
-10-10ºC | Machine oil | N22 | 170ºC | 19.8-24.2(40ºC) | -15ºC | GB443-84 |
-30-30ºC | Refrigerator oil | HD-13 | 160ºC | 11-15(50ºC) | -40ºC | Y1213-79 |
Malfunction | Cause | Solution |
Machine difficult to operate or empty wagon abnormally |
Dirty in back head cylinder or valve components | Clean parts and remove dust |
Burr | Use oilstone to clean burr | |
Lack of air-leg thrust |
If air-leg abrase or damage,change it | |
If seal parts damage,change it | ||
If pressure regulating valve seal ring damage, change it | ||
Wrong shank dimension | Standard shank dimension is 108±1mm | |
Vibration |
If the angle between air-leg and floor is too large or thrust is not enough, change angle or increase thrust. | |
If shank sleeve abrase,change it | ||
If drill is flex,change it | ||
Bad lubricate | Oil standard lubrication oil | |
Water intake | If water tube broken,change it | |
If water tube sleeve abrase or broken, change it | ||
If drill block,change it | ||
Rotate drill to be not good |
Ratchet pawl abrase | Adjust machine or change it |
Crowned spring damage | Change spring | |
Ratchet abrase | Adjust another side or change it |